{"product_id":"mb92-moisture-analyzer-110v","title":"Ohaus MB92 Moisture Analyzer 110V","description":"\u003cp\u003e\u003cstrong\u003eOhaus MB92 Moisture Analyzer 110V\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe Ohaus MB92 110V Moisture Analyzer delivers high-performance moisture analysis for demanding laboratory, education, pharmaceutical, food-processing, and industrial applications. Carbon fiber heating, a full-color capacitive touchscreen, flexible drying profiles, and a tool-free heating chamber make it easier to create methods, protect data, and maintain the instrument.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCarbon fiber heating technology with a full-color capacitive touchscreen\u003c\/li\u003e\n\u003cli\u003eFlexible Ramp, Standard, Step, and Fast drying profiles\u003c\/li\u003e\n\u003cli\u003eTimed, automatic, manual, and custom shut-off criteria\u003c\/li\u003e\n\u003cli\u003eEnhanced password protection for data security and integrity\u003c\/li\u003e\n\u003cli\u003eFull glass panel and tool-free heating chamber assembly for easier cleaning and maintenance\u003c\/li\u003e\n\u003cli\u003eLive drying curve and on-screen operating instructions\u003c\/li\u003e\n\u003cli\u003eMulti-color status light, USB device, USB host, and RS232 communication\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e✅ Ships direct from Ohaus Corporation (Worthington, OH)\u003cbr\u003e✅ Orders typically process and ship within 3–5 business days\u003cbr\u003e✅ Full manufacturer warranty from Ohaus\u003cbr\u003e✅ 7-day price-match guarantee\u003cbr\u003e✅ Alaska, Hawaii, and international shipping available by quote — contact us at 1-800-577-0501\u003c\/p\u003e\u003ch5\u003eTechnical Specs\u003c\/h5\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003e\u003cp\u003eSpecification\u003c\/p\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cp\u003eMB92 110V\u003c\/p\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Capacity\u003c\/td\u003e\n\u003ctd\u003e90 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReadability (Moisture Content)\u003c\/td\u003e\n\u003ctd\u003e1 mg \/ 0.01%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePan Size (Diameter)\u003c\/td\u003e\n\u003ctd\u003e90 mm (3.5 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeater Type\u003c\/td\u003e\n\u003ctd\u003eCarbon fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e352 x 210 x 138 mm (13.9 x 8.3 x 5.4 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdjustment\u003c\/td\u003e\n\u003ctd\u003eTemperature adjustment - mechanical (100°C, 160°C); weight adjustment - external (50 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eUSB device; RS232; USB host\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e4.3 in capacitive touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Results\u003c\/td\u003e\n\u003ctd\u003eRG%; temperature; drying curve; DC%; time; method name; statistics; MC%; weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Profiles\u003c\/td\u003e\n\u003ctd\u003eRamp; Standard; Step; Fast\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eID Management\u003c\/td\u003e\n\u003ctd\u003eSample name; sample ID; batch ID\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIn-use Cover\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Start Weight\u003c\/td\u003e\n\u003ctd\u003e0.5 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMoisture Range\u003c\/td\u003e\n\u003ctd\u003e0.01% – 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e4.3 kg (9.5 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Range (Temperature)\u003c\/td\u003e\n\u003ctd\u003e10°C – 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Instructions\u003c\/td\u003e\n\u003ctd\u003eLive drying curve; on-screen instruction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Moisture Content (MC%)\u003c\/td\u003e\n\u003ctd\u003e0.5% – 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability\u003c\/td\u003e\n\u003ctd\u003e0.08% (3 g sample); 0.015% (10 g sample)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShut-Off Criteria\u003c\/td\u003e\n\u003ctd\u003eTimed; 5 auto; manual; custom - user-set weight loss\/time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Light\u003c\/td\u003e\n\u003ctd\u003eMulti-color status light\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStored Results\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTare Range\u003c\/td\u003e\n\u003ctd\u003eTo capacity by subtraction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e40°C – 200°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Library\u003c\/td\u003e\n\u003ctd\u003e20 methods\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Weight\u003c\/td\u003e\n\u003ctd\u003e50 g, OIML F2 or ASTM Class 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e110V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Purpose\u003c\/td\u003e\n\u003ctd\u003eMoisture analysis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarket Worlds\u003c\/td\u003e\n\u003ctd\u003eIndustrial; education; pharmacy; laboratory; food\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eChina\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch5\u003eApplications\u003c\/h5\u003e\u003cul\u003e\n\u003cli\u003eFood processing and preparation environments\u003c\/li\u003e\n\u003cli\u003eWastewater treatment plant sample analysis\u003c\/li\u003e\n\u003cli\u003eClassroom and education environments\u003c\/li\u003e\n\u003cli\u003eLaboratory and contract laboratory testing\u003c\/li\u003e\n\u003cli\u003eLight industrial and industrial environments\u003c\/li\u003e\n\u003cli\u003ePharmacy school and pharmaceutical production applications\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch5\u003eDownloads\u003c\/h5\u003e\u003cp\u003eManufacturer documentation for the MB92 110V is being sourced and will be added here shortly.\u003c\/p\u003e\u003ch5\u003eReturns\u003c\/h5\u003e\u003cp\u003eOhaus: Standard products may be returned within 30 days of delivery (20% restocking fee, minimum $100). Items must be unopened and in original packaging.\u003c\/p\u003e","brand":"Ohaus","offers":[{"title":"Default Title","offer_id":48890144587970,"sku":"30971930","price":5397.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0658\/7691\/8466\/files\/MoistureAnalyzerMB92110V.jpg?v=1789951691","url":"https:\/\/labstockdirect.com\/products\/mb92-moisture-analyzer-110v","provider":"Lab Stock Direct","version":"1.0","type":"link"}